Sign In | Join Free | My burrillandco.com
Home > IMU Accelerometer Gyro >

Low Drift IMU Sensor With ADIS16488 Protocal

Shenzhen Fire Power Control Technology Co., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers
     
    Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers
    • Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers
    • Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers
    • Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers
    • Buy cheap Low Drift IMU Sensor With ADIS16488 Protocal from wholesalers

    Low Drift IMU Sensor With ADIS16488 Protocal

    Ask Lasest Price
    Model Number : 16488-H
    Payment Terms : T/T
    Supply Ability : 500/month
    Delivery Time : 10 days for sample
    Brand Name : Firepower
    Certification : CE ROHS
    • Product Details
    • Company Profile

    Low Drift IMU Sensor With ADIS16488 Protocal

    MEMS IMU with protocal same as ADIS16488

    Technical specification

    ParameterConditions16488-Hunit
    GyroDynamic measuring rangeconfigurable±500º/s
    Bias instabilityAllan<2º/h
    bias stability10s,rms<10º/h
    bias in full temperature range-40℃~85℃,10s,rms<50º/h
    Random walk<0.15º/√h
    Scale factor is nonlinear
    <500ppm
    Constant error of scale factor
    <2000ppm
    bias repeatability<10º/h
    Effect of linear acceleration on bias<10º/h/g
    The influence of vibration on bias is changed before and after vibration<10º/h/hg
    The influence of vibration on bias, vibration changes after vibration<10º/h/g
    Noise
    0.001°/s/√Hz
    Resolution
    3.052×10−7º/s/LSB
    AccelerometerDynamic measuring rangeConfigurable (Max ±40)±16g
    Bias
    1mg
    bias stabilityAllan error0.1mg
    bias in full temperature range-40℃~85℃,1б0mg
    Bias repeatability
    0.5mg
    Random walk0.029m/s/√h
    Noise density
    0.025mg/√Hz
    Constant error of scale factor
    2000ppm
    scale factor nonlinear
    500ppm
    bandwidth(-3dB)
    200Hz
    MagnetometerDynamic measuring range
    ±2.5gauss
    Bias
    15mgauss
    BarometerPressure range
    300~1100mbar
    sensitivity
    6.1 × 10-7mbar/LSB
    Total error
    4.5mbar
    The relative error
    2.5mbar
    nonlinearity
    0.1%FS
    Communication interface1 way SPIInput clock frequency200~1000Hz
    1 way UARTBaudrate200~1000Hz
    Electrical characteristicsvoltagedc3.3(or5)±10%V
    Power consumption
    0.6W
    Environmentworking temp.extensible-40℃~85℃
    vibration
    10~2000Hz,6.06g
    impact
    1000g,0.5ms



    16488-H is a high accuracy MEMS IMU with protocal same as ADIS16488. The product precision is better than ADIS16488. The version is optional, the size and appearance are exactly the same, and the communication protocol is the same.The version is optional, the size and appearance are exactly the same, and the communication protocol is the same. It is more convenient for users to change, providing users with professional product customization services.


    Quality Low Drift IMU Sensor With ADIS16488 Protocal for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Fire Power Control Technology Co., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)